Dsc 4000 User Manual

To see more than you've ever seen from Differential Scanning Calorimetry. Turn to PerkinElmer, where DSC was. The DSC 4000 offers dependable performance and.

. Jan 11, 1993 Software Version 1.3 SYSTEM MANUAL PC4OOO Book 4. This manual is for the PC4000 software version 1.3. Digital Security Controls Ltd. 160 Washburn St., Lockport, NY 14094. The PC4216 may be in accordance with installer programming. Installed in the main cabinet or in other cabinet options The basic 16 zone capability of the PC4000 can be and is shipped as a board only.

Expanded using either PC4108 or PC4116 modules. SYSTEM OVERVIEW Maximum System Capabilities Supervised Alarm Output Control Units - 1 PC4000 Main Board Bell Output, 700 mA fused at 5 Amps, 12 VDC unregulated 128 Zones PC4000 Main Board: 16 zones Steady or Pulsed Output PC4108 Expansion Module: 8 zones. COMBUS Power and Operation the most economical use of system modules; two eight The PC4000 main board can provide up to 500 mA to zone expansion modules instead of one sixteen zone, power modules, keypads and devices. A PC4204 power. Select a dry location close to an unswitched AC source, a ground connection and a telephone connection for When the PC4000 is first powered up all zones on the mounting the Main Control Cabinet.

Main board and User Codes are assigned to Partition 1. Now that the Partitions have been defined, zones programmed and access codes assigned you are The PC4000 can also be reset through software in the ready to program the rest of the system. It is best to installer’s programming. See “Factory Default” in the follow the Programming Work Sheets starting at the Programming Guide. PC4000 MAIN BOARD SPECIFICATIONS Control Panel Output Voltage 16 zones Typically, with normal AC on and a fully charged battery, the output voltage will be 13.8 VDC. With AC off and the 16 fully programmable supervised zones (EOL battery discharging, the voltage will go below 10 volts. Nominal current draw of 25 mA 8 modules programmable as alarm annunciators or Provides Tamper and Trouble Reporting Codes zone followers Low COMBUS supervision to PC4000 Main Board Four wire (QUAD) hook-up to COMBUS Nominal current draw of 35 mA PC4116 Expansion Module.

Use a 16.5 VAC transformer with a minimum 40 VA the “GRN” terminal. The COMBUS is wired in the same rating to supply AC power to the PC4000. The manner on all modules. The COMBUS is used by the transformer should not be connected to an outlet that is main panel to communicate with and supply power to controlled by a switch. COMBUS for 5 seconds and resets the main panel. No programming will be lost and the time will The PC4000 can have up to 128 zones.

These zones not have to be reprogrammed. A system reset should can be divided by the installer into 8 separate be done if there is a COMBUS Communications fault partitions, that can be armed and disarmed separately.

A default installer’s programming code “4000” is the premises, the system will, at the end of the Exit delay programmed into the PC4000. This code is used with time, arm with interior zones automatically bypassed if the 8 command by the installer to gain access to those interior zones have been programmed as “Home.

Loss of Time.When the PC4000 is powered up, the remain ON until the trouble is cleared. Trouble internal time of day clock needs to be set to the correct conditions can also be transmitted to the monitoring time. Aux supply is use. It can create or delete other System Master Codes overloaded, a 4204 Aux trouble is generated. Or perform any other user feature the PC4000 user is capable of doing. Alarm Memory Display System Master Codes can do anything on the system.

0 Program Code - When selected, the keypad will Programming Additional Access Codes display ‘Enter Digits’ and what is currently programmed Using a System or Partition Master Code for that access code. Enter in the 4 digit code. Do not 1 Press the , then 5 key to enter the User press or # while entering the access code. The Auto Arm Control options can only be accessed if two seconds, sounds the keypad’s for 2 seconds, tests Auto Arm is enabled for the partition. The PC4000 can the main board battery voltage and sends a test code be programmed to arm a partition at the same time transmission to the monitoring station.

+6+Access Code+6 +8+Installer’s Code This function enables two special event messages to The PC4000 is completely programmed from the keypad be displayed when one of the special events occurs. By using commands in the 8 section. The commands are described in detail in the Programming Manual. An 80 character printer is strongly recommended. Configuring the Printer 1. Serial interface 2.

Dsc 4000 User Manual

Baud rate = 300, 600, 1200 or 2400 (PC4000 default setting = 1200 baud) 3. Parity = None 4. Character length = 8 bits 5. Auto line feed = Off 6. Assembly Plant 06/04/94 02:09 ALARM Front Office The PC4400 sends events to the printer as they occur. If the printer is off line or disconnected, the PC4000 keeps new events in memory until they are ready to be printed. When the printer is brought back on line, the PC4400 will send the new events to the printer.

Phone lines are not necessary to download to the panel located either on site, or communicate over the phone. If the computer is at the same location as the PC4000. The tip and ring lines of the modem can be directly The DSC downloading package version 5.0 or later. LIMITED WARRANTY Digital Security Controls Ltd. Warrants that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfillment of any breach of such warranty, Digital Security Controls Ltd.

© 1993 Digital Security Controls Ltd. Toronto, Canada Tel:800 387 3630 FAX: 905 760 3034. 29000223 R0. Book 3 - PC4000 Programming Manual Explains each section of installer’s programming. Book 4 - PC4000 System Manual Introduces the PC4000, explains the hookup and wiring, and user’s programming and functions. 1 PC4000 Main Control Board 1 LCD4500 Remote Keypad. Prevents the Installer’s code and the downloading access code from being reset to factory default when a software or hardware reset occurs.

Manual

PC ID Restores. Page 23 If this option is enabled the PC4000 will transmit the zone restoral reporting codes instead of the zone alarm reporting codes for partial closing identification.

To see more than you've ever seen from Differential Scanning Calorimetry (DSC), turn to PerkinElmer, where DSC was invented. Our comprehensive line of high-performance DSC applications, instruments and services – combined with our expertise in materials characterization - helps you push the envelope on your research, offering deeper insights and the best user experience available. Whether you are performing QA/QC, studying processes in polymers or pharmaceuticals, or developing the cures of tomorrow, our DSC solutions will open your eyes to a world of exciting new opportunities.

Posted on